Velp FIWE3 Raw Fiber Extractor
Fiber Analyzers that use pre-heated reagents for fiber analysis according to Weende, Van Soest and other official methods.
Raw Fiber Analyzer - Crude Fiber, Neutral & Acid Detergent Fiber
FIWE is a fiber analyzer suitable for raw fiber extraction, conventionally known as an indigestible residue.
The Weende method is the oldest analytical procedure still in use today, in which fiber concentration is measured as crude fiber (CF).
Weende method has been now largely replaced by the Neutral Detergent Fiber (NDF), a method developed by Van Soest, being now the most common measure of fiber used for animal feed analysis. It measures most of the structural components in plant cells (including lignin, hemicellulose and cellulose), but not pectin.
Another application is Acid Detergent Fiber (ADF), that is a portion of the plant fiber and includes cellulose, lignin and variable amounts of xylans.
FIWE fiber analyzer is also suitable for Acid Detergent Lignin (ADL) determination and Wijkstrom technique, a modification of Weende method.
Raw Fiber Analyzer - High Reliability, Single or Multiple Extractions
Perform single or multiple extractions including boiling, rinsing and filtration steps with the maximum reproducibility available.
No sample transfer prevents any possible sample loss, as crucibles can also be used as sample vessels during weighing, drying and washing.
Pre-heat the reagents with RC2 hot plate (included), and pour them directly into the system.
Raw Fiber Analyzer - Impressive Heating Element
An extremely efficient heating element speeds up the analysis, ensuring a rapid heating of the sample, previously mixed with pre-heated reagents.
Also after the second reagent addition, the heating element grants a fast re-heating of the solution, for cospicuous saving in terms of time.
In fact, FIWE Series drastically reduces the time required for the analysis: the equivalent manual procedure will require more than 6 hours, compared to the 2 hours with FIWE
High Performance
- Rapid analysis – 2 hours vs. 6 hours with manual systems
- Reliable results
- High reproducibility
- Back-pressure pump prevents clogging of crucibles
Versatile
- Total raw fiber extraction using Weende technique
- Neutral & acid detergent fiber with NDF, ADF, Van Soest extractions
- Acid detergent lignin extraction with ADL & Van Soest methods
- Fiber fraction analysis (cellulose, hemicellulose & pectin)
- Links boiling, rinsing and filtration
- Single or multiple samples can be processed
Full System
- Reagent preheating on RC 2 hotplate (provided)
- Same crucibles used for weighing, drying & washing – no loss
Choice of Models
- FIWE is available in different configurations: FIWE 3, a 3-position raw fiber analyzer FIWE 6, a 6-position raw fiber analyzer
GENERAL FEATURES | |
Construction material: | epoxy painted stainless steel structure |
Type of extractions: | cold and hot extractions |
Number of samples: | FIWE 3 3 positions FIWE 6 6 positions |
Samples: | individually processed |
Sample quantity: | from 0,5 to 3 g |
Sample removal: | air pump |
Reagent discharge: | peristaltic pump |
Digital timer: | 0 - 99 minutes with acoustic signal at the end |
Temperature: | electronic regulation |
Reagents and cooling water : | separated outlets |
Power: | FIWE 3 900 W FIWE 6 1200 W |
Weight: | FIWE 3 35 Kg (77 lb) FIWE 6 40 Kg (101.2 lb) |
Dimensions (WxHxD): | FIWE 3 530x620x390 mm (20.9x24.4x15.4 in) FIWE 6 760x620x390 mm (29.5x24.4x15.4 in) |
PERFORMANCE | |
Reproducibility (RSD): | ± 1% |
APPLICATIONS | |
Raw fiber (Weende, Wijstrom) | |
Neutral or acid detergent treatment fiber (Van Soest) | |
Lignin, Cellulose, Hemicellulose |
Including
Heat shieldFIWE 3: 40000167 FIWE 6: 40000161
|
PVC tube10001086
|
Glass crucible P2 - 6pcsA00000140
|
RC2 hot plateF20700430
|
Reagent glass bottle10001112
|
|||||
Pincer for crucibles10000247
|
Crucibles holderFIWE 3: 40000166 FIWE 6: 40000160
|