Binder KBW Series Climate Chamber with Illumination

Climate chamber with illumination

The BINDER climate chamber with illumination of the KBW series achieves homogeneous light distribution with its natural illumination. That allows this climate chamber to create constant lighting and temperature conditions.

Binder KBW Series Climate Chamber with Illumination

Electronically controlled APT.line™ preheating chamber assuring temperature accuracy and reproducible results

BINDER KBW Series models are available with internal capacities ranging from 240 - 720 litres.
  • Temperature range 0 °C to 70 °C (without illumination)
  • Temperature range 5 °C to 60 °C (with illumination)
  • 2 variable positioned illumination cassettes with 5 daylight illumination tubes, each, in steps switchable
  • The patented illumination system assures an unique homogeneous light distribution
  • MP controller with 2 programs with 10 sections each, alternatively switchable to 1 program with 20 sections
    • Integrated week program timer with real time function
    • Digital temperature setting with an accuracy of a tenth of a degree
    • Adjustable ramp functions via program editor
    • Adjustable fan speed
    • Elapsed time indicator
  • Access port Ø 30 mm, left side
  • Inner glass door
  • Independent adjustable temperature safety device class 3.1, providing full protection against chamber over-temperature, with visual and audible temperature alarm
  • RS 422 interface for communication software APT-COM™ DataControlSystem
  • Adjustable intervals for printer
  • 2 stainless steel racks
  • BINDER test confirmation
BINDER KBW Series: Optional extras include:
BINDER KBW Series (E5.1)
Access ports with silicone plug 30, 50, 100 mm O
Securing elements for additional fastening of racks (1 set of 4 pieces) O
Additional PT 100 temperature sensor, flexibly installed, with external connection, including DIN connector (6-pin) O
Ethernet interface for communication software APTCOM™ DataControlSystem O
Factory calibration certificate. Measurement in center of chamber at 37 °C or at specified testing temperature O
Extension to factory calibration certificate. Each additional measurement at an additional measuring point or temperature O
Temperature measurement acc. to DIN 12880 (27 measuring points) at 37 °C or at specified temperature with measuring protocol and certificate O
Data Logger Kit T 220: For the continuous temperature recording of -90 °C to 220 °C. Kit includes 1 data logger, PT 100 sensor with 2 m Teflon extension cable and 1 fixture for the connection at the BINDER unit O
Data Logger Software: Configuration und evaluation software for all BINDER Data Logger Kits, incl. data cable (RS 232) O
Rack, stainless steel O
Shelf, perforated, stainless steel O
Reinforced rack, stainless steel, with 1 set of securing elements (1 set of 4 pieces), max. load 70 kg O
Vibration compatible shelf / platform (positioned at bottom level) to be mounted inside the chamber for shaker / spinner / roller operation. Other positions available on request O
Temperature safety device, class 3.3 (DIN 12880) with optical alarm O
Analog temperature output, 4-20 mA, with 6-pin DIN socket (output not adjustable) O
Zero-voltage relay outputs accessible via 6-pin DIN socket. Additional module for controlling 2 relay outputs via 2 of the programmable controller’s controller contacts. Outputs can be switched on and off either automatically, or also manually O
Waterproof interior socket 230 V AC (max. 200 W), IP65 protected, with corresponding plug (IP66 protected) Max. allowed operating temperature 50 °C O
FLUORA® growth lamps set as replacement for the standard tubes for 230 V O
Arabidopsis fluorescent tubes set as replacement for the standard tubes for 230 V O
Replacement set of standard daylight illumination tubes for one illumination cassette O
Replacement set of FLUORA® illumination tubes for one illumination cassette O
Replacement set of Arabidopsis illumination tubes for one illumination cassette O
Locking door handle with key O